Customer and Project

AsterVale Solar EPC . Procurement manager Daniel Vega is developing a repeatable residential solar storage package for the Casa Oliva Solar Storage Project in Valencia, Spain.

The pilot scenario combines rooftop PV with indoor battery storage. The commercial focus is a clear specification, documented battery-inverter integration and a practical handover process for future residential EPC procurement.

Customer Requirements

The customer's example brief calls for storing daytime PV generation for evening use, supplying selected essential loads through a compatible backup system and fitting the battery into a dry utility room.

For procurement, the priorities are a clearly identified battery model, verifiable electrical ratings, predictable handling requirements and an installation checklist that local contractors can follow. Any expected electricity-cost reduction would require actual generation, load and tariff data.

System Configuration

The scenario uses one 1stess WYLD51.2V314AH LiFePO4 battery, with 51.2V nominal voltage, 314Ah capacity and 16.076kWh rated energy.

An 8kWp PV array and a 6kW low-voltage hybrid inverter are illustrative design assumptions. The exact inverter model is not specified or approved by this example. Its battery voltage range, charging limits, BMS protocol, firmware, cable pinout and PV input limits must be reviewed before selecting a real system.

The battery technical table lists 150A standard charging and 150A standard discharging. Maximum charging voltage is 57.4V and minimum discharge voltage is 43.2V. These are product ratings; actual operating settings must follow the approved model documentation


Installation and Delivery Sequence
  1. Requirements review: define the PV generation window, daily load profile, backup-load priorities and intended operating mode.
  2. Technical preparation: identify the battery model and review the inverter interface, electrical limits, documentation and site requirements.
  3. Delivery inspection: check product identity, enclosure condition, terminals, packaging and project documentation before installation.
  4. Positioning: move the 115kg battery with suitable handling equipment and place it on a level load-bearing indoor floor. The enclosure measures 740 x 395 x 250mm (H x W x D); ventilation and service access require additional space.
  5. Installation inspection: inspect the planned isolation, protection, cable route and communication connection against the approved system documents.
  6. Commissioning: verify settings, battery-inverter status and controlled charging/discharging under the selected equipment's approved procedures.
  7. Handover: retain the configuration record, inspection checklist and operator guidance for future service and procurement reference.

These stages describe a fictional case workflow, not an installation instruction or a record of work completed for a real customer.

Example Issue and Resolution

The fictional commissioning story introduces an initial CAN communication handshake failure caused by an incorrect protocol profile.

The scenario's support response is to check the inverter's supported battery profile, firmware and communication cable definition, then repeat battery-status and controlled operating checks. It does not establish universal inverter compatibility or provide a verified correction for any specific inverter model.

Illustrative Project Value

The sample handover gives the EPC a documented configuration, a practical installation checklist and a repeatable procurement brief for similar residential projects.

The intended energy-use benefit is to move some daytime PV generation to evening consumption and support selected backup loads through a compatible complete system. This case does not contain measured bill savings, guaranteed backup runtime, tested annual yield or a real customer testimonial.

Project Inquiry

For a residential solar battery project, send 1stess the inverter model, load profile, storage target, order quantity, destination and required market documents. Request the model-specific datasheet, compatibility review and project quotation.